Pool equipotential bonding conductors can be solid copper no smaller than what size?

8 AWG solid copper, insulated, covered or bare.

Start playing free

  1. 8 AWG ✔
  2. 14 AWG
  3. 12 AWG

Why: Section 680.26 uses a solid copper bonding conductor, 8 AWG or larger, which may be insulated, covered or bare. Its job is to reduce voltage differences around the pool.

Huh, didn't know that: Instead of 8 AWG copper, rigid brass conduit or another identified corrosion-resistant metal may be used.

The dad joke
The electrician's son was grounded by his parents. I heard them say he had no potential.
Like this card?
Play the game

References

Answer: 8 AWG. Section 680.26 uses a solid copper bonding conductor, 8 AWG or larger, which may be insulated, covered or bare. Its job is to reduce voltage differences around the pool.

  1. EC&M: Understanding Equipotential Bonding Requirements for Swimming Pools www.ecmweb.com/national-electrical-code/article/21268735/understanding-equipotential-bonding-requirements-for-swimming-pools-fountains-and-similar-installations
    a solid copper conductor, no smaller than 8 AWG that can be insulated, covered, or bare.
    Checked 2026-10-10.

Think this answer is wrong? Tap "Challenge this answer" on the card in the game and tell us why.

Test yourself in the game