Under the 2026 NEC, where must the service disconnect of a one- or two-family dwelling be?
Outdoors, readily accessible, and it serves as the emergency disconnect.
- Inside the garage only
- Readily accessible and outdoors ✔
- Inside the main bedroom
Why: The 2026 NEC 230.70(A)(1) requires an outdoor, readily accessible service disconnect for one- and two-family homes. It also doubles as the emergency disconnect.
Huh, didn't know that: Minnesota's 2026 guidance says utility-provided disconnects won't count as the emergency disconnect unless they meet 230.70.
Why did the main breaker move outside? It needed some space.
Like this card?
References
Answer: Readily accessible and outdoors. The 2026 NEC 230.70(A)(1) requires an outdoor, readily accessible service disconnect for one- and two-family homes. It also doubles as the emergency disconnect.
- EC&M: Top 25 Changes to the 2026 NEC ecmweb.com/national-electrical-code/article/55330438/top-25-changes-to-the-2026-national-electrical-code
The service disconnect must be readily accessible and located outdoors.
Checked 2026-10-10. - EC&M: Key Changes to the '26 NEC www.ecmweb.com/neca-show-coverage/article/55404442/key-changes-to-the-26-nec
The service disconnect will also serve as the emergency disconnect.
Checked 2026-10-10. - Minnesota DLI: 2026 National Electrical Code FAQ www.dli.mn.gov/sites/default/files/pdf/NECFAQ26.pdf
Utility-provided disconnects will no longer be accepted as the emergency disconnect unless they comply with Section 230.70.
Checked 2026-10-10.