Medium-pressure appliance under 200 lb, recovery equipment made after November 15, 1993. Evacuate to how many inches of mercury vacuum?

10 inches of mercury vacuum.

Start playing free

  1. 0 inches
  2. 10 inches ✔
  3. 15 inches

Why: Medium-pressure appliances, such as R-134a systems, with a full charge under 200 pounds must reach 10 inches of mercury vacuum with newer recovery equipment. Older equipment, made before November 15, 1993, only has to reach 4 inches.

Huh, didn't know that: Medium-pressure means a liquid saturation pressure between 45 and 170 psia at 104 F, and R-134a is one of EPA's examples.

The dad joke
How do you get straight A's? By using a ruler!
Like this card?
Play the game

References

Answer: 10 inches. Medium-pressure appliances, such as R-134a systems, with a full charge under 200 pounds must reach 10 inches of mercury vacuum with newer recovery equipment. Older equipment, made before November 15, 1993, only has to reach 4 inches.

  1. 40 CFR 82.156 Required practices (Cornell LII) www.law.cornell.edu/cfr/text/40/82.156
    Medium-pressure appliance , or isolated component of such appliance , with a full charge of less than 200 pounds of refrigerant 4 10.
    Checked 2026-10-10.
  2. 40 CFR 82.152 Definitions (Cornell LII) www.law.cornell.edu/cfr/text/40/82.152
    liquid phase saturation pressure between 45 psia and 170 psia at 104 °F
    Checked 2026-10-10.
  3. 40 CFR 82.152 Definitions (Cornell LII) www.law.cornell.edu/cfr/text/40/82.152
    R-114, R-124, R-12, R-134a, and R-500
    Checked 2026-10-10.
  4. 40 CFR 82.161 Technician certification (Cornell LII) www.law.cornell.edu/cfr/text/40/82.161
    must be certified as Type II technicians
    Checked 2026-10-10.

Think this answer is wrong? Tap "Challenge this answer" on the card in the game and tell us why.

Test yourself in the game