Post-1993 recovery equipment, small appliance with a dead compressor. What percent must you recover?
80 percent when the compressor is not functioning.
- 90 percent
- 60 percent
- 80 percent ✔
Why: A broken compressor can't help push refrigerant out, so EPA lowers the target to 80 percent. If the compressor works, the target is 90 percent. A four-inch vacuum is an alternative to either percentage.
Huh, didn't know that: For dead compressors, EPA's Type I topics list heating and sharply striking the compressor to help free the refrigerant.
I gave all my dead batteries away today, free of charge.
References
Answer: 80 percent. A broken compressor can't help push refrigerant out, so EPA lowers the target to 80 percent. If the compressor works, the target is 90 percent. A four-inch vacuum is an alternative to either percentage.
- 40 CFR 82.156 Required practices (Cornell LII) www.law.cornell.edu/cfr/text/40/82.156
or 80 percent of the refrigerant in the appliance when the compressor in the appliance is not functioning
Checked 2026-10-10. - EPA Section 608 Technician Certification Test Topics www.epa.gov/section608/test-topics
heat and sharply strike the compressor
Checked 2026-10-10.
Think this answer is wrong? Tap "Challenge this answer" on the card in the game and tell us why.